Last reviewed: November 2026
In Greece, the fire protection rules for an apartment building depend on when the building was permitted. If a building got its permit from August 2018 onwards, it must follow the Building Fire Protection Regulation (Presidential Decree 41/2018), which means it needs a fire extinguisher on each floor of the shared areas, emergency lights, and clear escape signs. For taller buildings, there are even more requirements. But if the building’s permit was applied for before 17 February 1989, there is no fire protection legal framework to follow for the homes themselves. In every building, the shared areas are owned by all the owners together, and the building manager takes care of them on everyone’s behalf.
Key takeaways
- The rules follow the permit date: P.D. 41/2018 for new buildings, P.D. 71/1988 for those designed between 1989 and 2018, and no home fire protection framework for older blocks.
- In a building under P.D. 41/2018, the common areas need one portable extinguisher per floor, emergency lighting and safety signs.
- Nothing may be stored in the boiler room or fuel store, and escape routes must stay clear.
- This post sets out the rules as published at the review date above; the 2026 measures on the ministry’s site concern the clearing of plots.
Which fire regulation applies to residential buildings in Greece?
In Greece, the fire regulation for residential buildings depends on the date of the building permit. If a building went up a long time ago, it still follows the rules it was originally designed to meet.
| When the permit was applied for | What applies |
|---|---|
| Before 17 February 1989 | No fire protection legal framework for homes. The Fire Service proposes measures without imposing them. |
| From 17 February 1989 to August 2018 | P.D. 71/1988, the rules the building was designed under. |
| From 7 August 2018 | P.D. 41/2018 (Government Gazette A 80/7.5.2018), with a dedicated article on homes. |
P.D. 41/2018 came into effect three months after it was published. It applies to new buildings and some extensions or changes of use. However, a circular from the ministry in May 2019 made it clear that existing buildings are not automatically affected by it. If no new permit is required, the rules in place when the building was constructed still apply.
The rules are clear for the oldest homes – if the permit application predates the 1988 decree, there’s no fire protection legal framework for them. This is stated in a circular from the Fire Service, number 31415, issued in May 2019. The circular’s annex does suggest some measures that owners can take, but without binding conditions or penalties. For example, it recommends having one portable fire extinguisher on each floor, even in older buildings. These suggestions are based on P.D. 41/2018, and the circular recommends following the requirements that are feasible to carry out.
We’ve made a simple guide to what’s yours and what’s shared when you own a flat in a Greek apartment building.
What must the common areas have?
The rules that come next are based on the homes article of P.D. 41/2018, which binds the buildings that were permitted under it.
Fire extinguishers in a polykatoikia
The rule says you need a portable fire extinguisher on each floor, and it should be in the common areas, where everyone can get to it. Each extinguisher can cover an area of up to 400 square metres. If the floor is bigger, you’ll need more extinguishers. The decree also says that you have to take care of the fire equipment and check it, just like the manufacturer says to do.
Escape routes, lighting and signs
In an emergency, the stairs are the way to go, and a lift is never an escape route. In homes, escape routes need to be at least 0.80 metres wide. Apartment buildings need to have emergency lighting in the common areas and at the exits, as well as signs that show where the escape routes, exits and firefighting equipment are. If a building has three or more floors of main use, the decree also requires manual call points in the shared areas near the stairs, and automatic fire detection covering at least the bedrooms and kitchen. A permanent firefighting water network is only required for buildings that are over 28 metres high with a floor area of more than 500 square metres.
The boiler room and fuel store
A boiler room is considered a hazardous space if it has boilers that produce more than 50 kW of thermal output. This means it needs to be its own fire compartment. Boiler rooms are also equipped with carbon dioxide fire extinguishers, just like other plant rooms. You’re also not allowed to keep combustible things like firewood or household equipment in the boiler room or fuel store.
Storage in stairwells and basements
There’s a rule in the decree that says you can’t put furniture or objects in the way of escape routes or exits, not even for a little while. You also can’t cover up safety signs or the equipment used to put out fires. In older buildings, the building regulation (kanonismos) normally keeps the common areas open for everyone to use. The person in charge of the building can make sure people follow this rule.
What is required inside the flat, and what is simply sensible?
In an apartment, the rules pretty much decide how it’s built. Under P.D. 41/2018, each home is separated from the ones next door by walls and floors that resist fire, and the front door has a fire rating too.
The homes article also lists prohibitions that are good habits in any flat:
- keep heaters at a safe distance from anything that burns, and never stand them on rugs;
- never refuel an oil or paraffin stove while it is running or still hot;
- never move a gas stove while it is lit;
- have chimneys cleaned regularly.
If you have an older flat, it’s a good idea to have a portable fire extinguisher near the kitchen and make sure the electrical board is in good shape. You should also unplug things while the home stands empty. If your flat is near a forest or a big park, a separate regulation applies, with its own paperwork.
“When I visit a member’s flat I walk the stairs at least once instead of taking the lift. In five minutes you see whether the landings are clear, whether the extinguishers carry a recent service label, and whether anything is piled in the boiler room. If one of those is wrong, write to the manager that week and ask for it to go on the next assembly’s agenda.”
Yanis Zisis, Founder, Home Watch Athens
Who is responsible, who pays and how is it decided?
The decree says what a building has to have, but it doesn’t name who’s in charge of maintaining it. This is because the shared areas of the building are owned by all the owners together, and the manager takes care of them on behalf of everyone. If you want to know more, you can read our article on the building manager’s duties and limits.
When it comes to taking care of a building, there are expenses that everyone shares. This includes the periodic service of fire extinguishers or replacing emergency lights. These are listed on the koinoxrista statement. New equipment that the building has never had before is a different story. If you own in an older building, there’s no law that says you have to do it. Instead, the general assembly votes on it. If the owners decide to go ahead, the expense is split among all the flats according to the building regulation. We have a guide that explains how one-off building charges are approved and split.
If you’re living outside the country, someone can attend the meeting for you. Through our building meeting representation service in Athens, we go to the meetings for our members and tell them what was decided.
What does a building insurance policy ask?
In Greece, you don’t have to get insurance for your building, but if there is a policy, fire is its core cover. The insurance policy is a contract, so what’s written in it is what matters. We have a guide that explains insurance for a building’s common areas, which can help you figure out where the building’s policy stops and your own begins.
What should an owner abroad ask the manager?
Ask in writing:
- the year of the building permit, which tells you which rules apply;
- how many extinguishers the common areas have, where they are and when they were last serviced;
- whether the stairwell has working emergency lighting and exit signs;
- who holds the boiler room key, and whether anything is stored there or in the fuel store;
- for a copy of the building policy, if there is one;
- when fire protection was last on an assembly agenda.
The Ministry for Climate Crisis and Civil Protection puts out protection guidelines in English and several other languages. You can call the Fire Service on 199. There’s also 112, the European emergency number.
How current are these rules?
This post reflects the rules as published at the review date under the title. Greece set out fire protection measures on the ministry’s website in 2026, and they concern land. These rules, based on Law 5281/2026 and the joint ministerial decision that followed, say that plots need to be cleared every year from 1 April to 15 June, and a declaration has to be filed by 15 June. For homes, the decree we worked from is P.D. 41/2018, which covers the inside of residential buildings.
How Home Watch Athens can help
Yanis stops by each member’s home once a month and sends a photo update. If you need help with things like building matters or attending meetings, those are member services quoted separately. If you want someone in Athens who is familiar with your building, you can Apply for Membership.
Frequently asked questions
Is fire safety equipment compulsory in every apartment building in Greece?
No. Fire safety in an apartment building in Greece follows the permit date. Buildings permitted from 7 August 2018 must meet P.D. 41/2018, including an extinguisher on each floor of the common areas, emergency lighting and signs. Buildings permitted before 17 February 1989 have no fire protection legal framework for homes, and the Fire Service only proposes measures for them.
How many fire extinguishers does a polykatoikia need?
Under P.D. 41/2018, a polykatoikia needs one portable extinguisher on every floor, placed in the common areas, with each unit covering up to 400 square metres of floor area. The boiler room and other plant rooms have their own carbon dioxide extinguishers. An older building is not bound by these numbers, though the Fire Service proposes the same per-floor figure for it.
Can residents keep things on the landings or in the boiler room?
In buildings under P.D. 41/2018, no. The decree forbids placing furniture or objects on escape routes and exits, even temporarily, and storing combustible items in the boiler room or fuel store. In older buildings the building regulation usually reserves the common areas for shared use, and the manager can ask for items to be removed.
Who pays for fire equipment in the common areas?
All the owners, through the shared expenses. Servicing existing extinguishers or replacing an emergency light is a routine item on the koinoxrista statement. Buying and fitting equipment the building has never had is put to the general assembly and then divided among the flats under the building regulation.