A bathroom without a window renovation in Greece succeeds or fails on ventilation. Before you think about tiles, work out how the damp air will leave the room, which duct or shaft it will use and how the fan will be switched. Then plan bright, layered lighting, simple controls and a proper handover, so the bathroom stays dry whether someone lives there full-time or it sits empty between visits.
Key takeaways
- Decide the ventilation route first: an existing duct, a shared shaft or a new route above the ceiling.
- Works in common parts, such as a shared shaft or the facade, need the co-owners’ consent.
- Wire the fan to the light with a run-on timer.
- Ask for photos of the duct before the ceiling is closed, and a handover showing every control.
- In a home you visit only for short stays, dry drain traps and a fan left off cause most problems on arrival.
Why so many Greek apartments have a bathroom without a window
In a lot of Athens apartment buildings, known as polykatoikia, the bathroom sits in the middle of the floor plan, next to the shared waste stack and the internal light well. The ventilation in these bathrooms is often basic: sometimes just a small grille leading to a shaft, sometimes nothing at all except the door.
That copes when someone is at home every day. When the home is empty for months or used for a few weeks a year, steam has nowhere to go, the grout turns black and a stale smell builds up behind the closed door.
A renovation, even a partial one, is the perfect time to fix this, since the ceiling and walls are already open. Make ventilation the core of the project, not an afterthought.
Planning a bathroom without a window: renovation priorities in Greece
Before you approve any design from abroad, ask your builder or engineer to answer four questions on site:
- Where does the existing ventilation go, if anywhere, and does it actually draw air?
- Is the route private to your apartment, or does it use a shaft or duct shared with other flats?
- Is there space above the ceiling for a fan and duct, and how low would a false ceiling sit?
- Is there a gas appliance anywhere nearby, such as a boiler or water heater?
The answers decide the layout. Our guide on whether you need a permit to renovate an apartment in Greece explains the approval routes you may need. Watch the building itself, particularly common parts such as light wells, shared shafts, the roof and the facade. As of November 2026, the Ministry of Environment and Energy’s decision on small-scale works approval requires a declaration of consent from the co-owners where works take place in common areas. Discuss any new duct outlet with the building administrator early, and check the building regulation, the kanonismos, for rules on shafts and outlets.
Choosing the ventilation route
Using an existing duct or shared shaft
If your bathroom already has a working duct to the roof, reusing it is usually simplest. Get it checked and cleaned out first, because old ducts are often blocked.
If you share a ventilation shaft with other apartments, install a backdraught shutter so air only flows out, and check how your neighbours use the shaft before connecting to it.
Creating a new route through the ceiling
Where nothing usable exists, the usual fix is an in-line fan above a false ceiling, with a duct running to an outside wall or a balcony. Keep the duct as short and straight as you can, use rigid, smooth duct where possible, and slope it slightly towards the outside so condensation doesn’t drip back into the room. A new hole in the external wall changes the facade, which belongs to all the owners, so this is where the co-owners’ consent matters most.
Replacement air and gas appliances
A fan can only remove air if air can enter the room, so leave a small gap under the door or fit a door grille. If there is a gas boiler or water heater in the apartment, ask a licensed gas installer to check that a powerful fan won’t interfere with it. Enaon EDA, the gas distributor in Attica, states in its guidance on the correct operation and maintenance of a gas installation that any intervention in ventilation openings that could reduce the air supply is prohibited, so never close or reuse a gas vent for the bathroom.
Lighting a room with no daylight
Without a window, a single ceiling light rarely does the job. Plan layers:
- General light: two or more ceiling downlights suitable for damp rooms, spread so the shower area is not in shadow.
- Mirror light: a lit mirror or lights at the sides of the mirror, so faces are evenly lit for shaving or make-up.
A neutral to warm white light feels natural without daylight, and pale tiles, a big mirror and a clear glass screen make the room feel brighter.
Electrical work near a shower or bath follows safety rules for wet areas that limit where fittings go. Hire a licensed electrician and ask for the installer’s declaration, known as the YDE. HEDNO’s form covers modifications as well as new installations.
Controls that keep the bathroom dry
A fan is useless unless someone turns it on. For a bathroom with no window, the simplest set-up is to wire the fan to the light switch, with a run-on timer that keeps it working for a set time after the light goes off. Many fans also offer a humidistat, which turns the fan on when the air gets humid and off once the room is dry again.
A few details make daily use easier:
- Choose a quiet fan, so nobody is tempted to switch it off.
- Fit an isolator switch outside the bathroom for maintenance, and label it.
- Ask for the run-on time to be set before handover, not left at the factory setting.
Maintenance after the renovation
Clean the fan grille every few months and the fan itself once a year, because dust quickly reduces airflow. Check that the backdraught shutter opens freely when the fan runs and closes when it stops. Replace the silicone around the shower and basin at the first sign of black spots.
Drain traps matter just as much. When an apartment is empty, the water in the traps dries up and smells from the waste pipes seep into the room. That’s why we run every tap and flush the toilet during each monthly property check: it refills the traps and keeps the smell away. If the flat is an older one, our guide to renovating an old apartment in Athens covers what tends to be hiding behind the walls.
“When I take over a windowless bathroom, I test the fan with a sheet of toilet paper before anything else. If the paper does not stick to the grille, the room is not being ventilated, whatever the label says. At handover I always show the owner the switch, the run-on timer and the isolator, because a fan nobody understands is a fan that stays off.”
– Yanis Zisis, Founder of Home Watch Athens
Handover and using the bathroom during short stays
What a good handover includes
Before you accept the work, ask for:
- photos of the fan, duct route and outlet taken before the ceiling was closed
- a demonstration of the light, fan, run-on timer, humidistat and isolator
- the fan model, manual and warranty, and the electrician’s declaration
- a note of where any access hatch for the fan sits
If you’re abroad, someone can do the walk-through for you and take photos, as long as every control is tested.
Arriving for a short stay
When you arrive, run every tap and flush the toilet straight away. Then switch on the fan and let it run for about half an hour with the door open.
Leaving again
Before you go, dry the shower screen and floor and hang towels outside the bathroom. Let the fan finish its run-on cycle, then leave the bathroom door slightly open so the room can dry out while the apartment is closed up.
How Home Watch Athens can help
We carry out bathroom renovations in Athens as well as overseeing them. Before you approve a design, we check the ventilation route and the building’s rules on site. You’ll get photo updates at each stage, including the fan and duct before the ceiling is closed. Works start from €600/m² (excluding 24% Greek Tax), and contractor quotes in Greece often end up higher than first quoted, so we agree a written scope first. You can read more about our renovation services in Athens, or Apply for Membership and Yanis will reply within 24 hours.
Frequently asked questions
Is a bathroom without a window allowed in a Greek apartment?
In practice, yes. Internal bathrooms are very common in Greek apartment buildings, particularly in Athens, and are normally ventilated with an extract fan connected to a duct or shaft. Whether a specific new layout meets the building rules is a question for your engineer. If a renovation adds a new outlet in a common part of the building, the co-owners’ consent is needed.
What size of extract fan does a windowless bathroom need?
It depends on the room’s volume and the length of the duct. A small bathroom with a short duct needs a modest fan, while a long route needs a stronger, usually in-line, fan to overcome the resistance. Ask your electrician or installer to size it for the actual duct route rather than choosing by price or appearance.
Can I connect my bathroom fan to the building’s light well?
Sometimes, but only with the building’s agreement, because light wells and shared shafts are common parts. Some buildings have rules in their regulation about what can be connected or fixed there. Fit a backdraught shutter so air flows only outwards, and think about your neighbours’ windows if any open onto the same shaft.
Why does my windowless bathroom smell after the flat has been empty?
The most common cause is dry drain traps. The water seal in the shower, basin and floor drains evaporates over weeks, letting smells rise from the waste pipes. Running the taps and flushing the toilet refills them. If the smell continues after that, have a plumber check the seals and the connection to the stack.
Should the bathroom fan be left on while the apartment is empty?
Usually not continuously. Let it complete its run-on cycle after your last shower, leave the bathroom door ajar and keep the electricity on, so a humidistat fan can still react if humidity rises. A monthly visit that airs the home, runs the taps and checks for moisture does more than a fan running alone for months.
This guide is general information, not legal or technical advice. For your own situation, you can always consult a lawyer or a licensed engineer.
Last updated: November 2026